PSL Weekly Report FAMIS #10368)

Today is maintenance day and there are people working in the enclosure at this time.


Laser Status:
SysStat is good
Front End Power is -0.002978W (should be around 30 W)
HPO Output Power is 0.3117W
Front End Watch is RED
HPO Watch is RED

PMC:
It has been locked 0 days, 0 hr 40 minutes (should be days/weeks)
Reflected power = 16.24Watts
Transmitted power = 48.17Watts
PowerSum = 64.4Watts.

FSS:
It has been locked for 0 days 0 hr and 9 min (should be days/weeks)
TPD[V] = 2.464V (min 0.9V)

ISS:
The diffracted power is around 0.24% (should be 3-5%)
Last saturation event was 0 days 0 hours and 40 minutes ago (should be days/weeks)

Possible Issues:
Front End Power is Low
ISS diffracted power is Low
LRA out of range, see SYSSTAT.adl

 