Displaying report 1-1 of 1.
Reports until 11:03, Wednesday 08 August 2018
H1 SQZ
daniel.sigg@LIGO.ORG - posted 11:03, Wednesday 08 August 2018 (43323)
Boost/notch filters in CM slow path

Marc Daniel

We added the boost/notch filters, D1000798-v2, to the slow path of all squeezer common mode boards. The measured transfer function is pretty close to the theoretical one, see T1800112-v1.

Displaying report 1-1 of 1.