Displaying report 1-1 of 1.
Reports until 13:28, Tuesday 14 August 2018
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 13:28, Tuesday 14 August 2018 - last comment - 09:05, Wednesday 15 August 2018(43421)
CDS maintenance summary

WP7765 CDS WAP configuration standardization

Dave, Carlos:

All 6 CDS WAPs (wireless access points) now share a common networking configuration.

WP7774 Replacing h1sush2a One Stop fiber

Richard, Dave:

As part of the investigation into h1sush2a's recent instability, we replaced the One Stop fiber for a spare line today. Details in separate alog.

WP7770 ISI-HAM[2,3] GS13 cable and model switching

Hugh, Dave:

New models for h1isiham[2.3] were installed to match the GS13 field cabling changes made today. Also the updated BIO parts were added to the models.

WP7749 Removal of temporary GS13 fast channels from frame

Hugh, Dave:

New h1isiham[2,3,4] models were installed which remove the temporary GS13 DQ channels from the frame (six per model).

Vacuum Controls end station ion pump addition

Patrick, Dave:

h0vacey was modified to add IP17, h0vacex was modified to add IP18. A new INI file was created for each system.

Slow Controls Wind Fence channels added to h1ecaty1plc1

Patrick, Dave:

h1ecaty1plc1 was modified to add its wind fence channels. A new INI file was created.

DAQ Restart

Dave:

The DAQ was restarted at 13:07 PDT to support:

h0vacex and h0vacey new IP channels.

h1ecaty1plc1 new wind fence channels.

h1isiham[2,3,4] removal of temporary GS13 channels.

Comments related to this report
david.barker@LIGO.ORG - 14:43, Tuesday 14 August 2018 (43423)

BTW: h1sush2a stopped running at 13:19 UTC today (06:19 PDT), just in time for maintenance.

david.barker@LIGO.ORG - 09:05, Wednesday 15 August 2018 (43440)

model restarts logged for Tue 14/Aug/2018
2018_08_14 10:32 h1iopsush2a
2018_08_14 10:32 h1susmc1
2018_08_14 10:33 h1iopsush2a
2018_08_14 10:33 h1susmc1
2018_08_14 10:34 h1susmc3
2018_08_14 10:34 h1suspr3
2018_08_14 10:34 h1susprm
2018_08_14 10:37 h1isiham2
2018_08_14 10:37 h1isiham3
2018_08_14 13:00 h1isiham4
2018_08_14 13:05 h1isiham4
2018_08_14 13:09 h1broadcast0
2018_08_14 13:09 h1dc0
2018_08_14 13:09 h1fw0
2018_08_14 13:09 h1fw1
2018_08_14 13:09 h1fw2
2018_08_14 13:09 h1nds0
2018_08_14 13:09 h1nds1
2018_08_14 13:09 h1tw0
2018_08_14 13:09 h1tw1

Displaying report 1-1 of 1.