Reports until 17:52, Saturday 18 August 2018
H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 17:52, Saturday 18 August 2018 (43511)
IFO locking
TVo, Stefan

We worked on getting the IFO locking again:
- As we went through the  initial alignment we noticed a few things:
  - ALS arm initial alignment: The camera feed-back gains are extremely low - we were able to increase the gain by x100 to make it converge faster. Also the ITMY green camera is now centered, and H1:ALS-X_CAM_ITM_PIT_OFS and  H1:ALS-X_CAM_ITM_YAW_OFS are updated to reflect the same alignment as before.
   - Even though not needed, we also tried the automatic INPUT_ALIGN_YARM states, but the ALIGN_IFO guardian always failed in PREP_INPUT_ALIGN_YARM. So we skipped it for today.
   - MICH_DARK: we just used MICH_DARK_LOCKED, and tweaked the BS by hand.
 - Then we started full locking and had no problem getting to RESONANCE. ITMY IR and AS cameras are now centered as well.
 - We then manually stepped through CARM_TO_ANALOG until line 1716, ALS-C_REFL_DC_BIAS','FM1','ON'.
 - Then our day was halted by an 8.2mag earthquake in Fiji.