Displaying report 1-1 of 1.
Reports until 08:26, Monday 20 August 2018
H1 PSL
travis.sadecki@LIGO.ORG - posted 08:26, Monday 20 August 2018 - last comment - 17:52, Tuesday 21 August 2018(43523)
PSL Weekly

Laser Status:
SysStat is good
Front End Power is -0.001465W (should be around 30 W)
HPO Output Power is 73.48W
Front End Watch is RED
HPO Watch is RED

PMC:
It has been locked 0 days, 4 hr 9 minutes (should be days/weeks)
Reflected power = 15.27Watts
Transmitted power = 41.38Watts
PowerSum = 56.64Watts.

FSS:
It has been locked for 0 days 11 hr and 29 min (should be days/weeks)
TPD[V] = 2.113V (min 0.9V)

ISS:
The diffracted power is around 3.2% (should be 3-5%)
Last saturation event was 1 days 18 hours and 52 minutes ago (should be days/weeks)

Possible Issues:
Front End Power is Low
LRA out of range, see SYSSTAT.adl

 

Comments related to this report
travis.sadecki@LIGO.ORG - 08:32, Monday 20 August 2018 (43524)

Someone from Team PSL should look into why the Front End Watch is red and the Front End Power is being reported as zero when it is actually not.

travis.sadecki@LIGO.ORG - 11:41, Monday 20 August 2018 (43532)

FRS ticket 11302 created.

edmond.merilh@LIGO.ORG - 16:08, Monday 20 August 2018 (43542)

The FE power was being reported by a power meter inside the HPO which is no longer included in the beam path. The new reading wil come from the pick-off that was installed at the output of the MOPA in conjunction with the 70W amplifier installation (channel for this TBA). I'm not sure about the FE watchdog showing RED. HPO WD needs to be changed to amplifier(or something) WD and LRA range is no longer of any use.  Also, I noticed that output power of the new amp is being reported as the HPO power (simple metadata change?). Everything else looks ok. I can look into this further and see about working on getting that MEDM screen/channels edited.

jason.oberling@LIGO.ORG - 17:52, Tuesday 21 August 2018 (43572)

The script used to create the above report needs to be updated (it's on my list to sit down with TJ and do this).  As Ed says, the FE power is being measured by a PD that is no longer in use; a new one has been installed and the channel exists (H1:PSL-AMP_PWR4 if I remember off the top of my head correctly).  The watchdog was red because it was OFF, so the report was functioning as intended here.  We also need some name changes for some of the items (HPO Output Power should be something like "70W Amp Output Power" and likewise for the watchdog), as well as an edit of the System Status check to match the changes for the 70W amplifier.

Displaying report 1-1 of 1.