Displaying report 1-1 of 1.
Reports until 18:27, Monday 20 August 2018
H1 SEI (SEI)
jenne.driggers@LIGO.ORG - posted 18:27, Monday 20 August 2018 - last comment - 18:49, Monday 20 August 2018(43544)
SEI ISI Config to MORE_WINDY

It's been pretty windy all afternoon, but the last hour or two it's a teeny bit more windy than it had been, and we've struggled to hold ALS lock (green arms are okay, but locking to the PSL is not okay).  So, I changed the ISI Config guardian to MORE_WINDY at about 18:05 Pacific (01:05 UTC). 

At the same time, I did an initial alignment (just in case).  Between these 2 changes, and the wind is a teeny bit better again, we're holding lock a little better. 

Comments related to this report
jenne.driggers@LIGO.ORG - 18:49, Monday 20 August 2018 (43546)

The wind speed has started dropping, so I have reverted the ISI config to its nominal state of WINDY at about 18:48 Pacific, 01:48 UTC.

Displaying report 1-1 of 1.