Displaying report 1-1 of 1.
Reports until 16:34, Tuesday 21 August 2018
H1 DAQ
david.barker@LIGO.ORG - posted 16:34, Tuesday 21 August 2018 (43569)
h1nds1 (default NDS) crashed at 15:25 PDT

h1nds1 commenced a retransmission sequence starting at 15:24:27 which ultimately caused its demise at 15:25:16

Immediately preceding the first retransmission request were a rapid sequence of second trend requests, each about 7 minutes in duration (and some duplicated) for the channel H1:LSC-MCL_IN1_DQ

monit restarted h1nds1.

Displaying report 1-1 of 1.