Displaying report 1-1 of 1.
Reports until 23:32, Tuesday 21 August 2018
H1 SEI
thomas.vo@LIGO.ORG - posted 23:32, Tuesday 21 August 2018 (43578)
strange motion of the optics today

Our optics are moving more than they should be with the ground motion we have right now.  It seems to be sudden glitches, which seem to be impacting mulitple suspensions. 

We can see that if we sit with just the green arms locked ITMY optical lever seems to have 0.5 urad glitches.  ETMY also shows some glitches.  The Y arm ALS control signal also shows these large glitches, and when we lock the interferometer these glitches also show up in IMC F..

Was there some configuration change today that might have caused this? 

It doesn't look like any of our ISI to suspension FF is engaged now. 

Images attached to this report
Displaying report 1-1 of 1.