edmond.merilh@LIGO.ORG - posted 16:13, Thursday 23 August 2018 (43625)
AA Chassis/PEM MIC channels repaired
I removed AA chassis S1300104 to repair channels 2, 7, and S1001053 channel 29. In all 3 cases the 8627 op amp at the input had to be replaced. The units are now fully functional and they have been returned to service. WP 7788.