Reports until 19:03, Friday 24 August 2018
H1 ISC
stefan.ballmer@LIGO.ORG - posted 19:03, Friday 24 August 2018 (43649)
ASC-AS_C whitening gain lowered by 18dB
The high violin modes were saturating the ASC-AS_C diode, breaking the SRC2 alignment loop.

We lowered its whitening gain from 36dB to 18dB (H1:ASC-AS_C_WHITEN_GAINSTEP from 12 to 6). Note that will mess with the ASC-AS_C calibration, so once the violins are down, we should bring it up again.