Reports until 16:49, Saturday 25 August 2018
H1 ISC
stefan.ballmer@LIGO.ORG - posted 16:49, Saturday 25 August 2018 (43659)
OMC length integrator FM2 had history always on
The guardian had trouble locking the OMC - it found the resonance, but then jumped away when trying to engage the length loop. We tracked it down to an "always on" setting in the FM2 integrator. Set it to "zero history", which fixed the problem.