TMS motion decoupling from SOFT d.o.f.s

This morning I locked the IFO up to ENGAGE_SRC_ASC (so the soft degrees of freedom were still uncontrolled).

I then measured the response of the transmission QPDs to CSOFT, DSOFT and TMS motions. Results are below

Pitch response

  CSOFT_PIT DSOFT_PIT TMS X PIT TMS Y PIT
H1:ASC-X_TR_A_PIT_INMON 0.034320 0.033126 0.082365 -0.000413
H1:ASC-X_TR_B_PIT_INMON -0.032526 -0.034011 0.161257 -0.000336
H1:ASC-Y_TR_A_PIT_INMON -0.000844 -0.002045 0.000469 0.087232
H1:ASC-Y_TR_B_PIT_INMON -0.184214 0.190121 0.000034 0.179455

Yaw response

  CSOFT_YAW DSOFT_YAW TMS X YAW TMS Y YAW
H1:ASC-X_TR_A_YAW_INMON -0.013011 -0.013201 0.107712 0.000346
H1:ASC-X_TR_B_YAW_INMON 0.138074 0.132226 0.230404 -0.000457
H1:ASC-Y_TR_A_YAW_INMON 0.004750 -0.015159 0.000380 0.101773
H1:ASC-Y_TR_B_YAW_INMON -0.150895 0.150881 0.000959 0.188005

The inverse matrixes, which should provide us the signals for the soft loops that are decoupled from the TMS motions are below:

Pitch inverse matrix

  H1:ASC-X_TR_A_PIT_INMON H1:ASC-X_TR_B_PIT_INMON H1:ASC-Y_TR_A_PIT_INMON H1:ASC-Y_TR_B_PIT_INMON
CSOFT_PIT 10.158285 -5.203855 5.463542 -2.642115
DSOFT_PIT 9.558392 -4.866796 -5.456120 2.665092
TMS X PIT 4.065558 4.124789 -0.025037 0.029256
TMS Y PIT 0.300411 -0.186573 11.388809 0.036760

Yaw inverse matrix

  H1:ASC-X_TR_A_YAW_INMON H1:ASC-X_TR_B_YAW_INMON H1:ASC-Y_TR_A_YAW_INMON H1:ASC-Y_TR_B_YAW_INMON
CSOFT_YAW -6.916193 3.236467 5.394202 -2.899484
DSOFT_YAW -6.184460 2.887779 -5.511869 3.002154
TMS X YAW 7.692627 0.743966 -0.052039 0.015826
TMS Y YAW -0.627030 0.276288 8.753197 0.582431

New sensing matrix

With the measurement above, and rescaling to maintain similar values, the sensing matrix should be

C SOFT PIT TRX A TRX B TRY A TRY B
New -0.619 0.317 -0.333 0.161
Old -0.691 0.381 -0.639 0.361

 

D SOFT PIT TRX A TRX B TRY A TRY B
New -1.114 0.567 0.636 -0.311
Old -1.114 0.686 0.355 0.201

 

C SOFT YAW TRX A TRX B TRY A TRY B
New 0.684 -0.320 -0.533 0.287
Old 0.684 -0.316 -0.681 0.319

 

D SOFT YAW TRX A TRX B TRY A TRY B
New 0.684 -0.320 0.610 -0.332
Old 0.684 -0.316 0.681 -0.319

This new matrix has been uploaded to the guardian code (in PREP_ASC_FOR_FULL_IFO)