Displaying report 1-1 of 1.
Reports until 10:42, Friday 31 August 2018
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 10:42, Friday 31 August 2018 (43772)
Quick Check-in on SUS Coil Driver Monitor Screens
J. Kissel
FRS Ticket 10349

Stuart had identified a bug in the SUS Coil Driver Monitor screens at LLO (see LLO aLOG 38485) after he completed front-end / I/O chassis switcheroo that took place between sush2a, sush2b, and sush56 (see LHO aLOG 38827). He subsequently fixed the medm screens in April (see LLO aLOG 38510), and did so for all suspension types since it was identified to be a result of the added calibration filtering into the RMS IMON and VOLTMON paths in the library part 
/opt/rtcds/userapps/release/sus/common/models/
    FOUROSEM_MONITOR_MASTER.mdl. 

I'd apparently updated the screens locally on July 3rd,
    jeffrey.kissel@zotws10:/opt/rtcds/userapps/release/sus/common/medm$ ls -la */SUS_CUST_*_MONITOR_OVERVIEW.adl
    -rw-rw-r-- 1 jeffrey.kissel controls 147374 Jul  3 14:15 bsfm/SUS_CUST_BSFM_MONITOR_OVERVIEW.adl
    -rw-rw-r-- 1 jeffrey.kissel controls  16570 Jul  3 14:15 haux/SUS_CUST_HAUX_MONITOR_OVERVIEW.adl
    -rw-rw-r-- 1 jeffrey.kissel controls 214822 Jul  3 14:15 hxts/SUS_CUST_HXTS_MONITOR_OVERVIEW.adl
    -rw-rw-r-- 1 jeffrey.kissel controls 330694 Jul  3 11:54 quad/SUS_CUST_QUAD_MONITOR_OVERVIEW.adl
but didn't aLOG it. I log it here as proof that we have updated the screens here. 

Note, because some models haven't yet been compiled against the new version of FOUROSEM_MONITOR_MASTER.mdl (namely the ITMs and the BS), the RMS IMON and VOLTMON values on these models will remain white until we do so. We expect these remaining straggler bugs will resolve themselves during the RCG upgrade in mid-September.

I'm closing the ticket accordingly.