Georgia, Sheila
LSC things
ASC
While we were powering up I had a quick look on the Hartmann wavefront sensors. And earlier while the A2L scripts were running I did some violin mode work.
HWS
I restarted the Hartmann code for HWS-ITMX and HWS-ITMY while we were already at 7W (one by accident the other because it had been terminated). So the references for spherical power etc are all in a warming-up state, this was mostly an accident and it would be better to have cold references.
First attachment shows the laser power, and the spherical powers measured on ITMX ITMY and ETMY as we power up. The jumps are where I restarted the Hartmann code and it reset its references.
Second attachment shows contour plots.
For ITMX and ITMY the reference time is when we're partially warmed up. The bright ghost beam has returned to ITMX. (We originally blocked this with an iris, but then opened the iris during a CO2 test and found that the reflection had disappeared). This beam seems to dominate the measurement.
The ITMY measurement seems to show heating near the center of the optic (the centre of the optic corresponds to the centre of the previous ring heater test).
For ETMY the reference time is earlier, but confusingly it looks like the centre of the optic was cooling down. Not sure how to interpret this.
I did not notice the ETMX code was not running until later.
Violin modes
I updated the monitor filters on ETMY, and updated the frequencies on the violin mode overview screen. Since the last alog on this I think we've assigned many mode modes, and put them in the table and guardian:
701.755 Hz to ITMY
503.679 Hz, 503.734 Hz, 504.176 Hz, 505.0794 Hz, 505.286 Hz, and 510.714 Hz to ETMY,
508.938 Hz, and 526.781 Hz to ETMX.
Yesterday I thought I had found the settings for 504.145 Hz (ETMY MODE6), but had trouble damping it today with the same settings.