J. Kissel https://tinyurl.com/LIGOSUSActuatorTuning Table I've balanced the ITMX PUM/L2 coils using the demodulated optical lever method (LHO aLOGs 11392 and 9453). I'll characterize in more detail later, but here're the results: Former New % Difference 100*(former-new)/former UL +0.909 +1.13552 -24.92% LL -0.965 -0.973361 -0.86642% UR -1.035 -1.02334 +1.1266% LR +1.099 +0.877201 +20.182% These new balance values have been accepted into the SDF system. If anyone wants to get a jump on it, I've measured broad-band transfer functions characterizing the L 2 LPY, P 2 LPY, and Y 2 LPY transfer functions for the new balance. They live in templates here: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGL2/Data/ 2018-09-05_1602_H1SUSITMX_L2_WhiteNoise_L_0p02to50Hz.xml 2018-09-05_1602_H1SUSITMX_L2_WhiteNoise_P_0p02to50Hz.xml 2018-09-05_1602_H1SUSITMX_L2_WhiteNoise_Y_0p02to50Hz.xml