J. Kissel https://tinyurl.com/LIGOSUSActuatorTuning Table I've balanced the BS M2 coils using the demodulated optical lever method (LHO aLOGs 11392 and 9453). I'll characterize in more detail later, but here're the results: Former New % Difference 100*(former-new)/former UL +1.01 +1.00112 +0.87921% LL -0.985 -0.988984 -0.40447% UR -1.015 -1.01108 +0.38621% LR +0.99 +0.998824 -0.89131% Only a small change. They've been accepted into the SDF system. I was only able to grab an L drive transfer function with the new balance before the Mpc Train started choo-chooing (instead of the full frequency dependent suite of L, P and Y drive with former, no, and new balance). Anyways, the one TF lives here: /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM2/Data/ 2018-09-06_1900_H1SUSBS_M2_L_WhiteNoise.xml For the record, the balance and thees transfer functions were measured with the BS optical lever damping OFF.