Displaying report 1-1 of 1.
Reports until 21:40, Tuesday 18 September 2018
H1 AOS
sheila.dwyer@LIGO.ORG - posted 21:40, Tuesday 18 September 2018 - last comment - 09:44, Wednesday 19 September 2018(44047)
ITMY optical lever noisy

the ITMY optical lever is noisy (screenshot attached).  It would be a good idea to check for mechanical interferences when there is an oppurtunity. 

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 09:41, Wednesday 19 September 2018 (44058)

I did a walkthrough and a visual did not reveal any obvious mechanical coupling. Both piers were as isolated as usual.  Spectrograms were examined and besides optical motion there was no broadband glitching evident. We'll keep an eye on this.

jeffrey.kissel@LIGO.ORG - 09:44, Wednesday 19 September 2018 (44059)SUS
Created corresponding FRS Ticket 11493.
Displaying report 1-1 of 1.