Reports until 08:07, Wednesday 19 September 2018
LHO General
corey.gray@LIGO.ORG - posted 08:07, Wednesday 19 September 2018 - last comment - 08:34, Wednesday 19 September 2018(44053)
Morning Status

TITLE: 09/19 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.08 μm/s
QUICK SUMMARY:

Comments related to this report
corey.gray@LIGO.ORG - 08:34, Wednesday 19 September 2018 (44056)

ITMx Binary I/O M0 Control Test Coil Enable for State 2 issue

  • All other Test Masses are in State Request 2.0, but Jenne noticed ITMx has a RED bar for the TEST/COIL ENABLE (upper right on the main medm screen).
  • One can switch to State 0 & 1 and it is green and functioning, but seems to be an issue with State 2.  Richard said it looks like a software (vs hardware) issue.  So waiting on Rolf & Dave to take a look at this.