h1lsc0 crash at 3am, bad DAQ data from various front ends

At 10:08 UTC (03:08 PDT) it looks like h1lsc0 kernel panic'ed. Strangely we are getting bad DAQ data status from a strange collections of machines (all end stations which are on dolphin, corner ISC and susauxb123!) see attached image.

h1lsc0 console is showing a kernel panic error (I'll post it later).

I'll recover all systems execpt LSC before we start today's upgrade.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:46, Tuesday 25 September 2018 (44146)CDS
Opened corresponding to FRS Ticket 11528. Likely we can quickly close the ticket, since the system has been recovered, but I leave it open for Dave to comment as he sees fit.
david.barker@LIGO.ORG - 15:17, Tuesday 25 September 2018 (44149)

Here is the list of things I did until I was able to reset the DAQ status of these front end machines:

h1susauxb123: start streamers

h1lsc0: power computer down (after disabling its ix-dolphin switch port)

DAQ: restart

h1susauxb123: computer reboot. This system came back with no errors

h1asc0: computer reboot: This system came back with no errors

At this point, I could fix the DAQ mx stream on all the other models just by issuing a /etc/start_streamers.sh command.