Displaying report 1-1 of 1.
Reports until 10:32, Wednesday 26 September 2018
H1 SEI
edmond.merilh@LIGO.ORG - posted 10:32, Wednesday 26 September 2018 - last comment - 14:13, Wednesday 26 September 2018(44182)
H1 ISI CPS Sensor Noise Spectra Check - Weekly FAMIS #7562

I see elevated high freq in BS_ST1_CPSINF_H1_I, BS_ST2_CPSINF_V1_I, AND ITMY_ST1_CPSINF_V2

All other plots look nominally sound.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 14:13, Wednesday 26 September 2018 (44187)

Maybe Jim will toss in a plot, but it sounds like this time may have captured some lockloss(es), so integrated in a time when we were kicking ETMX, which back-reacted against the ISI.  Seems like no further investigation needed here, unless it continues to show up.

Displaying report 1-1 of 1.