Displaying report 1-1 of 1.
Reports until 14:26, Friday 05 October 2018
H1 ISC
gabriele.vajente@LIGO.ORG - posted 14:26, Friday 05 October 2018 (44361)
Improved OSA analysis script

I created an improved script to analyze the Optical Spectrum Analyzer data [the script can be found in /opt/rtcds/userapps/release/isc/h1/scripts/osa.py]

In summary:

gabriele.vajente@zotws2:~/$ /opt/rtcds/userapps/release/isc/h1/scripts/osa.py -h
usage: osa.py [-h] [-f FILENAME] [-t TIME] [-o OUTPUT] [-r REPROCESS]
optional arguments:
  -h, --help            show this help message and exit
  -f FILENAME, --filename FILENAME
                        File where the time series of sideband and carrier
                        powers will be saved
  -t TIME, --time TIME  Duration of plotting window in seconds
  -o OUTPUT, --output OUTPUT
                        Name of a folder where the average OSA scans will be
                        saved
  -r REPROCESS, --reprocess REPROCESS
                        Reprocess scans from a folder, and save a
                        reprocessed.txt file in there

When running online, the script produces a plot like the one below, taken during a power up.

 

The two left panels contains the time traces of the peak powers. The top panel shows the "simple" peak reconstruction as explained above (simply identify the 45MHz peaks, integrate their power, find the largest peak in the middle and integrate its power). The bottom panel instead shows the more "advanced" reconstruction of the 45 MHz, 9 MHz and carrier peaks, by fitting peaks at the correct frequencies.

The right panel shows the latest averaged scan (blue dots and trace) plus some fitting and peak identification traces: the red, green and magenta X show the peaks used for the "simple" reconstruction (time traces in the top left panel); the dashed curves show the individual fits to the sidebands and carrier peaks (time traces in the bottom left panel); the black trace shows the sum of all fitted sideband and carrier peaks.

The 9MHz sidebands are very close to the carrier peak. When at low power, it's hard to resolve them. Even at 10W, they barely make bumps on the side of the carrier peak. So their power measurement has a quite large uncertainty and should be taken with care.

Images attached to this report