aidan.brooks@LIGO.ORG - posted 14:57, Friday 05 October 2018 (44365)
Changing HWS gradient field data file format to HDF5 - first attempt failed

I've updated the HWS code so that the gradient field data is saved as HDF5 files instead of PICKLE files. I also updated the wavefront viewing utility so that it correctly extracts data from the new HDF5 files. I tested this at CIT on the HWS system and it worked pretty seemlessly.

Per work-permit 7857, I pulled the latest version of the code from the GIT repo on H1HWSEX and tried running it on that machine. It didn’t work because the H5PY package isn’t installed. I didn't have time to fix this issue so I reverted the version of the code to the earlier (working) version on GIT and restarted the HWS code.

Updating files:

Failure during execution:

Restoring earlier version of HWS_code

 

 

Images attached to this report