10Hz/60Hz pole/zero Pomona box added to LO slow output

Marc, Daniel, Nutsinee

We have to much gain at the output of the LO common mode board. The box has -41.5 dB gain up to 10Hz and -57dB gain above 60Hz. The box was installed last week. Combine with -30dB gain at the common path slide bar gives us UGF at 1kHz.

Images attached to this report