ITMX BIO

ITMX bio has the same problem we had before. 44046

 

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:08, Tuesday 09 October 2018 (44450)CDS
Attached is a trend of the H1:SUS-ITMX_BIO_M0_MON channel, showing that the state has be odd since Sept 25th 2018, which was first only F1. It began to be inhumanly flaky by Sept 29 2018 bouncing between F1 showing error and F1 & F2 in error. Then went high (with F1, F2, F3, and LF in error) on Oct 07, and came back again to F1 & F2 error on Oct 08 where it currently stands.

Opened FRS Ticket 11625.

As Sheila mentions, this appears to be strikingly similar to the issue reported in FRS Ticket 11492, and may even be related to an oldy-but-goldy FRS Ticket 5616.