I forgot which lock, but I measured MICH ctrl to DARM err for MICH FF.  I didn't (yet) get a chance to measure the FFpoint to DARM, but other than somewhat different AC coupling filters, this should be the same as for SRCL, since they're both just pushing on the differential ITMs. FF measurement xml files are attached.  The FF_point_2_DARM is measured using the SRCLFF1, with that version of AC coupling.  Undoing this AC coupling and applying the MICHFF AC coupling should allow for the fitting of the MICHFF as well.

Lock lengths so far today:

We do want to calibrate the IFO, but we should also carve out some time to just let the IFO sit untouched to see how long we can really stay at 20W on the lownoise ESD ETMX, perhaps during the site weekly meeting this afternoon.