Displaying report 1-1 of 1.
Reports until 08:51, Friday 12 October 2018
H1 ISC
gabriele.vajente@LIGO.ORG - posted 08:51, Friday 12 October 2018 - last comment - 15:05, Friday 12 October 2018(44513)
Morning lock report
Comments related to this report
gabriele.vajente@LIGO.ORG - 09:20, Friday 12 October 2018 (44515)
  • Another unknown lock loss at abut 8:50am
  • Went directly to NOMINAL_LOW_NOISE
jenne.driggers@LIGO.ORG - 09:21, Friday 12 October 2018 (44518)

DHARD_P gain this last lock was just a bit too high.  I lowered it from -40 to -35.  This gain has been bouncing up and down the last few days, since we started going to 20W.  We need to measure this loop when we have a chance, and also tune the radiation pressure compensation for 20W (it's currently tuned for 10W, and we don't have power-dependent code in there). 

I did not put this gain change into the guardian, since -40 worked earlier today and all yesterday.

haocun.yu@LIGO.ORG - 15:05, Friday 12 October 2018 (44527)

Jenne, Sheila (Sheila, logged in as Haocun by mistake)

We think the problem with DHARD that Jenne is talking about above is due to a bounce mode being rung up a bit. Now that we have dampers they ring down on their own within a couple of minutes so we haven't tried to do anything about this, but if needed we could monitor the amplitude and wait for it to ring down before increasing the DHARD gain. 

Displaying report 1-1 of 1.