TCS adjustments

Gabriele, Jenne, Shiela, Hang, Craig and Danny

Images attached to this report
Comments related to this report
daniel.vander-hyde@LIGO.ORG - 12:31, Tuesday 16 October 2018 (44587)AWC, TCS
  • Ring Heater script was turned off prematurely around gpstime 1223726510.
  • The ITMY RH power is currently at 1.74 W (.87 W upper and .87 W lower) where it should have reached  1.85 W (.925 W upper and .925 W lower).  
  • As the RHs reach thermal equilibrium this .1 watt ring heater difference should equate to a 1.9 microdiopter difference in spherical power. 
  • The right heater power should be updated eventually but I'm hesitant to make any further ring heater changes right before we start locking again.