Displaying report 1-1 of 1.
Reports until 16:08, Tuesday 16 October 2018
H1 CDS
david.barker@LIGO.ORG - posted 16:08, Tuesday 16 October 2018 (44594)
New CDS overview showing new h1oaf1 front end computer

Attached is a plot of the new CDS Overview MEDM.

HWWD and Timing share lower-left area

Conlog and IFO removed

DAQ and commands moved down to share bottom-right area

Mid and End Stations slid downwards to make space for h1oaf1

top column header line removed, corner station slid upwards to make additional space for h1oaf1

h1oaf1 added below h1oaf0, currently only the h1iopoaf1 model is running on this computer

placeholders for new models h1seiproc, h1susproc, h1iscproc added *

h1iopoaf1 and h1ioplsc0 have a colour change to denote they are Dolphin timer master and slave units respectively **

* note that current place holders are not quite in the correct locations. h1oaf model will move to h1oaf1 computer and the new h1seiproc will most probably run on h1oaf0 computer due to its slow speed (4kH).

** h1oaf1 is unique in that it has no IO Chassis and obtains its timing from h1ioplsc0 via Dolphin. h1ioplsc0 is the timing master, h1iopoaf1 is a virtualIOP timing slave. This means that restarting h1ioplsc0 will require a restart of all the models on h1oaf1.

In the second attachment, the h1iopoaf1 virtualIOP GDS screen is shown against an regular IOP model. Note:

 

 

Images attached to this report