Displaying report 1-1 of 1.
Reports until 12:40, Tuesday 16 October 2018
H1 CAL (CDS, DetChar)
jeffrey.kissel@LIGO.ORG - posted 12:40, Tuesday 16 October 2018 - last comment - 08:32, Wednesday 17 October 2018(44588)
List of New/Updated Channels for GDS Consumption regarding Calibration
D. Barker, J. Kissel
WP 7850
ECR E1800246
IIET 11305

Some more belated documentation in support of the front-end model changes that we made last week in order to support new / updated calibration code for O3:
Below is an explicit list of front-end generated channels that need to be removed from the GDS broadcaster, and a list of the new channels that should be used instead and/or replaced. It's also attached for any user's convenience.
One can cross-reference the list of new (slow) channels in our documentation that supports the new calculation for time-dependence, T1700106.

Channels to be removed:

FAST CHANNELS:
    CAL-CS_LINE_SUM_DQ                           # Agreed, disappears (DARM_LINE no longer exists)
    CAL-DARM_CTRL_WHITEN_OUT_DBL_DQ              # Agreed, replaced by simply DARM_CTRL_DQ (which is, yes, whitened, and stored as a double)
    CAL-DARM_ERR_WHITEN_OUT_DBL_DQ               # Agreed, replaced by simply DARM_ERR_DQ (which is, yes, whitened, and stored as a double)
    CAL-INJ_ODC_CHANNEL_OUT_DQ                   # Agreed, removed because we'll never do hardware injections from the cornerstation (i.e. on the ESD)

SLOW CHANNELS:
    CAL-CS_TDEP_DARM_LINE1_REF_A_TST_IMAG        # Agreed, disappears (no more DARM_LINE)
    CAL-CS_TDEP_DARM_LINE1_REF_A_TST_REAL        #      |
    CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_IMAG       #      |
    CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_IMAG   #      |
    CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_INV_REAL   #      |
    CAL-CS_TDEP_DARM_LINE1_REF_A_USUM_REAL       #      V
    CAL-CS_TDEP_DARM_LINE1_UNCERTAINTY           #      --
    CAL-CS_TDEP_ESD_LINE1_REF_A_TST_NOLOCK_IMAG        # Agreed, disappears (renamed to SUS_LINE1)
    CAL-CS_TDEP_ESD_LINE1_REF_A_TST_NOLOCK_REAL        # Agreed, disappears (renamed to SUS_LINE1)
    CAL-CS_TDEP_ESD_LINE1_REF_C_IMAG                   # Agreed, disappears (renamed to SUS_LINE1)
    CAL-CS_TDEP_PCALY_LINE1_UNCERTAINTY                # Agreed -- made generic to P    CAL_LINE1
    CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_IMAG             # Agreed -- made generic to PCAL_LINE2
    CAL-CS_TDEP_PCALY_LINE2_REF_A_TST_REAL             #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_IMAG            #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_A_USUM_REAL            #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_IMAG       #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_C_NOCAVPOLE_REAL       #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_D_IMAG                 #     |
    CAL-CS_TDEP_PCALY_LINE2_REF_D_REAL                 #     V
    CAL-CS_TDEP_PCALY_LINE2_UNCERTAINTY                #     --
    CAL-CS_TDEP_PCALY_LINE3_UNCERTAINTY                # Agreed -- made generic to PCAL_LINE3
    CAL-CS_TDEP_PCALY_LINE4_REF_A_TST_IMAG             # Agreed -- made generic to PCAL_LINE2
    CAL-CS_TDEP_PCALY_LINE4_REF_A_TST_REAL             # Agreed -- made generic to PCAL_LINE4
    CAL-CS_TDEP_PCALY_LINE4_REF_A_USUM_IMAG            #     |
    CAL-CS_TDEP_PCALY_LINE4_REF_A_USUM_REAL            #     |
    CAL-CS_TDEP_PCALY_LINE4_REF_C_NOCAVPOLE_IMAG       #     | 
    CAL-CS_TDEP_PCALY_LINE4_REF_C_NOCAVPOLE_REAL       #     |
    CAL-CS_TDEP_PCALY_LINE4_REF_D_IMAG                 #     V
    CAL-CS_TDEP_PCALY_LINE4_REF_D_REAL                 #     --
    CAL-CS_TDEP_REF_CLGRATIO_CTRL_IMAG                 # Agreed -- no longer needed
    CAL-CS_TDEP_REF_CLGRATIO_CTRL_REAL                 # Agreed -- no longer needed             
    CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_IMAG             # Agreed -- renamed to (for a given SUS_LINE) INVA_$(ISOSTAGE)_RESPRATIO 
    CAL-CS_TDEP_REF_INVA_CLGRATIO_TST_REAL             # Agreed -- renamed to (for a given SUS_LINE) INVA_$(ISOSTAGE)_RESPRATIO 


New Channel List:

FAST CHANNELS: 
('IFO generic channel name' 'sample rate' 'data storage type')
(when sample rate not listed, rate is 16384 Hz)
   CAL-CS_DARM_ERR_DQ double
   CAL-CS_DARM_CTRL_DQ double

   CAL-CS_DELTAL_RESIDUAL_DQ double
   CAL-CS_DELTAL_CTRL_DQ 4096 double
   CAL-CS_DELTAL_CTRL_TST_DQ 4096 double
   CAL-CS_DELTAL_CTRL_PUM_DQ 4096 double
   CAL-CS_DELTAL_CTRL_UIM_DQ 4096 double
   CAL-CS_DELTAL_EXTERNAL_DQ

   CAL-CS_CFTD_DELTAL_RESIDUAL_DQ double
   CAL-CS_CFTD_DELTAL_CTRL_DQ 4096 double
   CAL-CS_CFTD_DELTAL_CTRL_TST_DQ 4096 double
   CAL-CS_CFTD_DELTAL_CTRL_PUM_DQ 4096 double
   CAL-CS_CFTD_DELTAL_CTRL_UIM_DQ 4096 double
   CAL-CS_CFTD_DELTAL_EXTERNAL_DQ

SLOW CHANNELS:
   CAL-CS_TDEP_PCAL_LINE1_CORRECTION_REAL
   CAL-CS_TDEP_PCAL_LINE1_CORRECTION_IMAG
   CAL-CS_TDEP_PCAL_LINE2_CORRECTION_REAL
   CAL-CS_TDEP_PCAL_LINE2_CORRECTION_IMAG
   CAL-CS_TDEP_PCAL_LINE4_CORRECTION_REAL      # yes 4, not 3
   CAL-CS_TDEP_PCAL_LINE4_CORRECTION_IMAG
   CAL-CS_TDEP_SUS_LINE1_REF_INVA_UIM_RESPRATIO_REAL 
   CAL-CS_TDEP_SUS_LINE1_REF_INVA_UIM_RESPRATIO_IMAG
   CAL-CS_TDEP_SUS_LINE2_REF_INVA_PUM_RESPRATIO_REAL 
   CAL-CS_TDEP_SUS_LINE2_REF_INVA_PUM_RESPRATIO_IMAG
   CAL-CS_TDEP_SUS_LINE3_REF_INVA_TST_RESPRATIO_REAL 
   CAL-CS_TDEP_SUS_LINE3_REF_INVA_TST_RESPRATIO_IMAG
   CAL-CS_TDEP_PCAL_LINE2_REF_C_NOCAVPOLE_REAL 
   CAL-CS_TDEP_PCAL_LINE2_REF_C_NOCAVPOLE_IMAG
   CAL-CS_TDEP_PCAL_LINE4_REF_C_NOCAVPOLE_REAL 
   CAL-CS_TDEP_PCAL_LINE4_REF_C_NOCAVPOLE_IMAG
   CAL-CS_TDEP_PCAL_LINE2_REF_D_REAL 
   CAL-CS_TDEP_PCAL_LINE2_REF_D_IMAG
   CAL-CS_TDEP_PCAL_LINE4_REF_D_REAL 
   CAL-CS_TDEP_PCAL_LINE4_REF_D_IMAG
   CAL-CS_TDEP_PCAL_LINE2_REF_A_UIM_REAL   
   CAL-CS_TDEP_PCAL_LINE2_REF_A_UIM_IMAG
   CAL-CS_TDEP_PCAL_LINE2_REF_A_PUM_REAL  
   CAL-CS_TDEP_PCAL_LINE2_REF_A_PUM_IMAG
   CAL-CS_TDEP_PCAL_LINE2_REF_A_TST_REAL  
   CAL-CS_TDEP_PCAL_LINE2_REF_A_TST_IMAG
   CAL-CS_TDEP_PCAL_LINE4_REF_A_UIM_REAL  
   CAL-CS_TDEP_PCAL_LINE4_REF_A_UIM_IMAG
   CAL-CS_TDEP_PCAL_LINE4_REF_A_PUM_REAL  
   CAL-CS_TDEP_PCAL_LINE4_REF_A_PUM_IMAG
   CAL-CS_TDEP_PCAL_LINE4_REF_A_TST_REAL  
   CAL-CS_TDEP_PCAL_LINE4_REF_A_TST_IMAG
   CAL-CS_TDEP_SUS_LINE1_REF_UIM_NOLOCK_REAL  
   CAL-CS_TDEP_SUS_LINE1_REF_UIM_NOLOCK_IMAG
   CAL-CS_TDEP_SUS_LINE2_REF_PUM_NOLOCK_REAL  
   CAL-CS_TDEP_SUS_LINE2_REF_PUM_NOLOCK_IMAG
   CAL-CS_TDEP_SUS_LINE3_REF_TST_NOLOCK_REAL 
   CAL-CS_TDEP_SUS_LINE3_REF_TST_NOLOCK_IMAG


This should help alleviate some of the problems that folks have been having with the GDS Broadcaster since last week's upgrade (e.g. LHO aLOG 44454).
Non-image files attached to this report
Comments related to this report
aaron.viets@LIGO.ORG - 16:05, Tuesday 16 October 2018 (44596)CDS, DetChar

In addition to Jeff's list, the GDS calibration pipeline also needs these:

Fast channels:

  • ODC-MASTER_CHANNEL_OUT_DQ (16384 Hz)   (Note - we may no longer need this in the near future.)
  • SUS-ETMY_L3_CAL_LINE_OUT_DQ (512 Hz)
  • SUS-ETMY_L2_CAL_LINE_OUT_DQ (512 Hz)
  • SUS-ETMY_L1_CAL_LINE_OUT_DQ (512 Hz)
  • CAL-PCALY_RX_PD_OUT_DQ (16384 Hz)
  • CAL-PCALY_TX_PD_OUT_DQ (16384 Hz)
  • PEM-EY_MAINSMON_EBAY_1_DQ (1024 Hz)
  • IMC-WFS_A_DC_PIT_OUT_DQ (2048 Hz)
  • IMC-WFS_B_DC_PIT_OUT_DQ (2048 Hz)
  • IMC-WFS_A_DC_YAW_OUT_DQ (2048 Hz)
  • IMC-WFS_B_DC_YAW_OUT_DQ (2048 Hz)
  • PSL-DIAG_BULLSEYE_YAW_OUT_DQ (2048 Hz)
  • PSL-DIAG_BULLSEYE_WID_OUT_DQ (2048 Hz)
  • PSL-DIAG_BULLSEYE_PIT_OUT_DQ (2048 Hz)
  • ASC-DHARD_P_OUT_DQ (512 Hz)
  • ASC-DHARD_Y_OUT_DQ (512 Hz)
  • ASC-CHARD_P_OUT_DQ (512 Hz)
  • ASC-CHARD_Y_OUT_DQ (512 Hz)
  • LSC-SRCL_IN1_DQ (16384 Hz)
  • LSC-MICH_IN1_DQ (16384 Hz)
  • LSC-PRCL_IN1_DQ (16384 Hz)

Slow channels (all 16 Hz):

  • CAL-CS_TDEP_SUS_LINE1_UNCERTAINTY
  • CAL-CS_TDEP_SUS_LINE2_UNCERTAINTY    
  • CAL-CS_TDEP_SUS_LINE3_UNCERTAINTY 
  • CAL-CS_TDEP_PCAL_LINE1_UNCERTAINTY
  • CAL-CS_TDEP_PCAL_LINE2_UNCERTAINTY
  • CAL-CS_TDEP_PCAL_LINE4_UNCERTAINTY
john.zweizig@LIGO.ORG - 18:45, Tuesday 16 October 2018 (44598)CDS, DetChar
The following channels in the list of channels to be added do not ppear in the H-H1_R frames:

CAL-CS_DARM_ERR_DQ
CAL-CS_DARM_CTRL_DQ
CAL-CS_DELTAL_RESIDUAL_DQ
CAL-CS_DELTAL_CTRL_DQ
CAL-CS_DELTAL_CTRL_TST_DQ
CAL-CS_DELTAL_CTRL_PUM_DQ
CAL-CS_DELTAL_CTRL_UIM_DQ
CAL-CS_DELTAL_EXTERNAL_DQ
CAL-CS_CFTD_DELTAL_RESIDUAL_DQ
CAL-CS_CFTD_DELTAL_CTRL_DQ
CAL-CS_CFTD_DELTAL_CTRL_TST_DQ
CAL-CS_CFTD_DELTAL_CTRL_PUM_DQ
CAL-CS_CFTD_DELTAL_CTRL_UIM_DQ
CAL-CS_CFTD_DELTAL_EXTERNAL_DQ
CAL-CS_TDEP_SUS_LINE1_REF_UIM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE1_REF_UIM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE2_REF_PUM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE2_REF_PUM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE3_REF_TST_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE3_REF_TST_NOLOCK_IMAG

But these do, and were in the list I originally compiled from lists I received from Maddie and Aaron...

CAL-CS_TDEP_SUS_LINE1_REF_A_UIM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE1_REF_A_UIM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE2_REF_A_PUM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE2_REF_A_PUM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE3_REF_A_TST_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE3_REF_A_TST_NOLOCK_REAL
CAL-DARM_CTRL_DBL_DQ
CAL-DARM_ERR_DBL_DQ
aaron.viets@LIGO.ORG - 19:30, Tuesday 16 October 2018 (44600)

These channel names (similar to the names Jeff suggested) do appear in the H-H1_R frames:

  • CAL-CFTD_DELTAL_CTRL_DBL_DQ 4096
  • CAL-CFTD_DELTAL_CTRL_PUM_DBL_DQ 4096
  • CAL-CFTD_DELTAL_CTRL_TST_DBL_DQ 4096
  • CAL-CFTD_DELTAL_CTRL_UIM_DBL_DQ 4096
  • CAL-CFTD_DELTAL_EXTERNAL_DQ 16384
  • CAL-CFTD_DELTAL_RESIDUAL_DBL_DQ 16384
  • CAL-DELTAL_CTRL_DBL_DQ 4096
  • CAL-DELTAL_CTRL_PUM_DBL_DQ 4096
  • CAL-DELTAL_CTRL_TST_DBL_DQ 4096
  • CAL-DELTAL_CTRL_UIM_DBL_DQ 4096
  • CAL-DELTAL_EXTERNAL_DQ 16384
  • CAL-DELTAL_RESIDUAL_DBL_DQ 16384

Perhaps Jeff or Evan can confirm whether these are the correct channels.

jeffrey.kissel@LIGO.ORG - 08:32, Wednesday 17 October 2018 (44614)
Yes -- apologies -- I'd forgotten that the RCG adds "_DBL" to channels stored at double precision. Aaron's list is correct.
Displaying report 1-1 of 1.