TCS adjustments at 10 W

Sheila, Jenne, Gabriele, Hang, and Danny

 

Comments related to this report
sheila.dwyer@LIGO.ORG - 23:34, Tuesday 16 October 2018 (44607)

As Danny says, the interferometer isn't stable with 20W of input power and these TCS settings, but we think that these settings have reduced the sideband imbalance.  

In our first attempt to power up to 20W with these settings, (SRC still uncontrolled) we saw an oscillation in DSOFT pitch at around half a Hz.  With the SRC uncontrolled we could have a worse coupling of differential arm power to the test mass pitch.  This is why Hang implemented a version of DSOFT P which is similar to our higher bandwidth DSOFT P. 44602

The next time we powered up there was a large oscillation in our vertex LSC loops at around 20 Hz.  Since we have seen that the sideband imbalance is better and that the ration of 9 to 45 is lower with these TCS settings, we probably need to retune the LSC phases and input matrix.  