Displaying report 1-1 of 1.
Reports until 21:58, Wednesday 17 October 2018
H1 TCS (AWC, TCS)
daniel.vander-hyde@LIGO.ORG - posted 21:58, Wednesday 17 October 2018 - last comment - 21:07, Thursday 18 October 2018(44634)
TCS change from 10-15-2018 to 10-17-2018

It might be useful to summarize the TCS changes made from Monday to today:

10-15-2017

  CO2X  CO2Y PRG RF18 
IFO COLD (2W) 0.5 W 0.66 W 49.5 94
IFO HOT (20 W) 0.11 W 0.09 W 47.5 52.5

ITMX RH @ 0 W

ITMY RH @ 1.04 W 

Please see first figure for relevant time series of a 20 W lock stretch

 

10-17-2017 

  CO2X CO2Y PRG RF18
IFO COLD (2W) 0.5  W 0.6  W 48 83.5
IFO HOT (20 W) 0.1 W  0 W  47 56

ITMX RH @ 0 W

ITMY RH @ 1.74 W 

Please see second figure for relevant time series of a 20 W lock stretch

 

OSA scans

The following two tables list the carrier and sideband power when at 20W: 

  10-15-2018 10-17-2018
carrier (counts) 826 856
9 MHz upper (counts) 1252 777
9 MHz lower  (counts) 589 617
45 MHz upper (counts) 1800 1828
45 MHz lower (counts) 2366 2158

The new TCS settings seems to have improved the balance between the 9 MHz sidebands, and RF18 when at 20 watts. 

 

TCS to do list: 

 

Images attached to this report
Comments related to this report
daniel.vander-hyde@LIGO.ORG - 21:07, Thursday 18 October 2018 (44668)

CO2X is now at .2 watts when PSL input is at 2W.  This was done because on Tuesday we tried to increase CO2Y to compensate for the ring heater change but it just made locking difficult. 