It might be useful to summarize the TCS changes made from Monday to today:
| CO2X | CO2Y | PRG | RF18 | |
| IFO COLD (2W) | 0.5 W | 0.66 W | 49.5 | 94 |
| IFO HOT (20 W) | 0.11 W | 0.09 W | 47.5 | 52.5 |
ITMX RH @ 0 W
ITMY RH @ 1.04 W
Please see first figure for relevant time series of a 20 W lock stretch
| CO2X | CO2Y | PRG | RF18 | |
| IFO COLD (2W) | 0.5 W | 0.6 W | 48 | 83.5 |
| IFO HOT (20 W) | 0.1 W | 0 W | 47 | 56 |
ITMX RH @ 0 W
ITMY RH @ 1.74 W
Please see second figure for relevant time series of a 20 W lock stretch
The following two tables list the carrier and sideband power when at 20W:
| 10-15-2018 | 10-17-2018 | |
| carrier (counts) | 826 | 856 |
| 9 MHz upper (counts) | 1252 | 777 |
| 9 MHz lower (counts) | 589 | 617 |
| 45 MHz upper (counts) | 1800 | 1828 |
| 45 MHz lower (counts) | 2366 | 2158 |
The new TCS settings seems to have improved the balance between the 9 MHz sidebands, and RF18 when at 20 watts.
TCS to do list:
CO2X is now at .2 watts when PSL input is at 2W. This was done because on Tuesday we tried to increase CO2Y to compensate for the ring heater change but it just made locking difficult.