H1 ISC (DetChar)
jenne.driggers@LIGO.ORG - posted 16:46, Wednesday 17 October 2018 - last comment - 15:52, Thursday 18 October 2018(44637)
60Hz line is very bad today

The 60Hz line is *very* bad today.  I don't think we noticed it yesterday since we weren't really going to Nom Low Noise, since we were doing TCS tuning instead.  But, it's incredibly clear that something happened between Monday and today that has made the 60Hz line very bad.  If DetChar wanted to have a look at what witnesses see this, that would be helpful. 

I don't think that anything happened with the ETMX ESD power supply yesterday.  (It was going to be swapped out, but JeffK asked around, and it doesn't sound like we got that far before the end of maintenance yesterday).

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 15:52, Thursday 18 October 2018 (44662)

Apparently the ETMY ESD driver had been removed on Tuesday, and the cables were left un-terminated.  The modifications to the driver are complete, so this afternoon the driver was re-installed, and now the 60Hz line is much improved. 