Displaying report 1-1 of 1.
Reports until 17:59, Saturday 20 October 2018
H1 CAL
aaron.viets@LIGO.ORG - posted 17:59, Saturday 20 October 2018 - last comment - 19:43, Wednesday 24 October 2018(44710)
Testing GDS calibration pipeline restarted on DMT3

With the new front-end channels added to the GDS frame broadcaster channel list, I just restarted the testing calibration pipeline on DMT3.  The restart occurred around GPS second 1224110900.  The only feature we are unable to test at the moment is the calibration line subtraction, due to a few front-end channels that are still unavailable:

CAL-CS_TDEP_SUS_LINE1_REF_A_UIM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE1_REF_A_UIM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE2_REF_A_PUM_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE2_REF_A_PUM_NOLOCK_IMAG
CAL-CS_TDEP_SUS_LINE3_REF_A_TST_NOLOCK_REAL
CAL-CS_TDEP_SUS_LINE3_REF_A_TST_NOLOCK_IMAG

 

Comments related to this report
aaron.viets@LIGO.ORG - 19:43, Wednesday 24 October 2018 (44802)

[Dave Barker, John Zweizig, Aaron Viets]

I restarted the calibration pipeline on the testing machine again to include calibration line subtraction, after Dave added the needed channels to the frame broadcaster.  The restart occurred around GPS second 1224470390.  John Z also restarted the DMTDQ process earlier today.

Displaying report 1-1 of 1.