Displaying report 1-1 of 1.
Reports until 09:30, Thursday 18 October 2012
H1 SUS
mark.barton@LIGO.ORG - posted 09:30, Thursday 18 October 2012 - last comment - 10:14, Thursday 18 October 2012(4474)
MC1 OL values, gains and offsets
Mark B. and Betsy B.

Yesterday afternoon, Betsy set up the MC1 for measuring OL values and I logged the values. Later, she set the OSEMs to half range (based on staging building gains and offsets).

This morning we computed the final offsets and gain and entered them into MEDM:

M1T1 25624.2 1.1708  12812.1
M1T2 28820.2 1.0409  14410.1
M1T3 27449.3 1.0929 13724.65
M1LF 27304.6 1.0987  13652.3
M1RT 23813.5 1.2598 11906.75
M1SD 25168.3  1.192 12584.15
M2UL 26288.6 1.1412  13144.3
M2LL 24343.8 1.2323  12171.9
M2UR   24540 1.2225    12270
M2LR 24557.9 1.2216 12278.95
M3UL 27280.5 1.0997 13640.25
M3LL 25514.3 1.1758 12757.15
M3UR 26364.8 1.1379  13182.4
M3LR 26645.6 1.1259  13322.8

I created two new scripts to make this easy:
^/trunk/Common/MatlabTools/logOSEMs_IN1_H1MC1.m logs the OL values
^/trunk/Common/MatlabTools/prettyOSEMgains.m creates a pretty table, as above.
Comments related to this report
betsy.weaver@LIGO.ORG - 10:14, Thursday 18 October 2012 (4476)

Images attached to this comment
Displaying report 1-1 of 1.