rana.adhikari@LIGO.ORG - posted 22:58, Tuesday 23 October 2018 - last comment - 07:06, Wednesday 24 October 2018(44771)
REFL9 RF level check

Craig, Rana

We checked the RF levels at the REFL9 demod board RF MON (-23 dB coupled output) with 50 Ohm terminated oscope.

So to convert this trace back into the input of the demod board we multiply by ~14.

From the scope trace, we can see that the fastest slew is ~140 mV / 10 ns (10 V/us). This is not a problem for the FET mixers on the board.

The slew rate limit of the RFPD output amp is 450 V/us, so we are from hitting the hard slew rate limit. The question that remains is how close can we be before there is some non-negligible downconversion.

Thinking back to the iLIGO days, we used to have trouble with the MAX4107 (450 V/us slew rate) when it was putting out ~150 mV-pk at 2*25 MHz (~30 V/us).

So I think if the LMH6642 distorts at the same fraction of slew rate as the 4107, we are close to seeing this excess noise. To be sure, we'll need to do a more careful and systematic test with some spare RFPD and demod electronics. Tricky.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 07:06, Wednesday 24 October 2018 (44777)

Something that we haven't done yet is the reduction of the 9MHz modulation depth by 6dB, once we're at high power.  We should see if this helps get us far enough away from these slew rate limits.