Reports until 14:57, Wednesday 24 October 2018
H1 ISC
gabriele.vajente@LIGO.ORG - posted 14:57, Wednesday 24 October 2018 (44791)
Retuned A2L

This morning I ran my A2L decoupling script. Results are below

H1:SUS-ITMX_L2_DRIVEALIGN_P2L_GAIN OLD = -1.9978 NEW = -2.1862
H1:SUS-ITMY_L2_DRIVEALIGN_P2L_GAIN OLD = -0.9144 NEW = -1.0859
H1:SUS-ETMX_L2_DRIVEALIGN_P2L_GAIN OLD = +4.3666 NEW = +3.9067
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_GAIN OLD = +3.6086 NEW = +2.9830
H1:SUS-ITMX_L2_DRIVEALIGN_Y2L_GAIN OLD = -0.4938 NEW = -0.3852
H1:SUS-ITMY_L2_DRIVEALIGN_Y2L_GAIN OLD = +0.5500 NEW = +0.4461
H1:SUS-ETMX_L2_DRIVEALIGN_Y2L_GAIN OLD = +2.6323 NEW = +2.7184
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_GAIN OLD = +3.2478 NEW = +2.9410