Displaying report 1-1 of 1.
Reports until 18:03, Thursday 25 October 2018
H1 ISC (ISC)
thomas.vo@LIGO.ORG - posted 18:03, Thursday 25 October 2018 - last comment - 20:28, Friday 26 October 2018(44843)
DARM Spectrogram during RF9 modulation depth change

Hang, TVo

Hang had most of the tools written up to run the spectrograms using jupyter notebook so i helped tune the notch filtering to get the normalized spectrogram of CAL-DELTAL_EXTERNAL_DQ

The first plot shows broadband DARM, and the second plot shows a zoomed in version from 30 to 200 Hz. By eye, there's not an obvious correlation between the amplitude square wave of DB9 modulation depth to DARM, except there's some extra noise at the 57-58 Hz region which might come from the Hartmann sensor sync frequency.  The third plot shows a zoomed-in time version during one of the glitchy times, there's an obvious broadband spike but there is also a long lasting one at the 57-58 Hz that lasts for a few minutes.

Images attached to this report
Comments related to this report
thomas.vo@LIGO.ORG - 20:28, Friday 26 October 2018 (44857)

Rana suggested that the color bar previously was hiding some artifacts that are more apparent with better plotting,  attached are the same graphs but making the colors in a tighter window. 

Images attached to this comment
Displaying report 1-1 of 1.