Updated suspension control filters for SRM, PRM and BS

I updated the control filters in CAL_SUM_PRCL, CAL_SUM_SRCL and CAL_SUM_BS to match what is now used in the suspension models.

Changes have been accepted into the SDF.

Comments related to this report
gabriele.vajente@LIGO.ORG - 11:55, Tuesday 30 October 2018 (44907)

I also updated the optical gains in the error signal calibration. Differences were small (within 20-30%)

gabriele.vajente@LIGO.ORG - 15:42, Tuesday 30 October 2018 (44923)

The M1 calibration path for PRCL is limited by numerical noise, which appears as a spurious increase of the high frequency noise floor in the calibrated PRCL signal.