MC3 Phase 2a testing results finally look much better!

Betsy, Mark

As Mark is still debugging the Matlab scripts which run the TFs, I went back to the "old" way and ran them via DTT.  All of today's data and plots have been committed to the svn repository with file names:

2012-10-19_1434_H1SUSMC3_M1_*  (TFs with Damping ON)

and

2012-10-19_1550_H1SUSMC3_M1_*  (TFs with Damping OFF)

 

Attached is the plot of this data compared with MC3 and MC1 data taken in the staging building.