ETMx & ETMy Charge Measurements

Came in a early to squeeze in ETM charge measurements.  Here are some notes:

Below are the slider values & brief notes/checks of the measurements for both ETMs as I was running.  I ended up running the full script which had 5-measurements for ETMx & ETMy.  As long as we had three good measurements for an ETM, then we are good.  A good measurement basically shows a matlab plot with an "X" on it.  Attached are measurements for ETMx & ETMy. 

Alignment slider values & brief notes/checks on measurements as I was running the procedure:

ETMx:  Pit:  +102.3 & Yaw:  -131.0

NOTES for ETMxSee attached plot with 3-good measurements + 1 bad one.  For the ETMx one, the first measurement did not look good for Pitch ( w/ no "X" and all four quadrants were a flat 0 urad/V); the next 3-measurements looked good.

ETMy (w/ ESD LR quadrant bad!):  Pit:  +122.3 & Yaw:  -125.9

NOTES for ETMySee attached plot with 3-good measurements.  For the ETMy, mainly had an "X", but the ETMy LR quadrant was 0 urad/V.  This is a known failure for the the ETMY ESD (FRS#10543).

Images attached to this report
Comments related to this report
georgia.mansell@LIGO.ORG - 23:45, Tuesday 30 October 2018 (44937)

I've added today's data to the long trend plots of effective bias voltage for each quadrant, see first attachment for ETMX and second attachment for ETMY (sorry about the annoying axes on ETMY). No surprises: the same trend on EX due to the induced polarization caused by the bias voltage, and fairly flat for EY.

Measurements taken before and after the ETMX 20-bit DAC install show the same actuation strength (within error bars), which is good. The channels these scripts store and calculate the drive voltage from are the L3_ESDOUTF out channels.

I think I might need to update the calibration the scripts for the other types of charge measurements, which, if I remember right, read out the MASTER_OUT channels but I haven't done this yet.