Displaying report 1-1 of 1.
Reports until 03:58, Sunday 04 November 2018
H1 ISC (ISC)
craig.cahillane@LIGO.ORG - posted 03:58, Sunday 04 November 2018 - last comment - 10:26, Sunday 04 November 2018(45000)
Injections Tonight
Frequency noise injections
Into CARM Servo Board EXC A via LSC-EXTRA_AO_2_EXC (Pic 1)

Inj Amp     Start Time     End Time
-------------------------------------
1e-2        1225337909     1225338605
3e-2        1225338652     1225340457
3e-3        1225340607     1225341956
1e-3        1225341989     1225344477


Intensity noise injections
Into PSL-ISS_SECONDLOOP_EXCITATION_EXC with the low pass disengaged

Inj Amp     Start Time     End Time
-------------------------------------
1e3         1225346150     1225347492
3e3         1225347687     1225348986
1e4         1225349022     1225350095
3e2         1225350140     1225351784
1e2         1225351821     1225353267


MICH Feedforward
I changed the actuators for the MICH FF to DARM measurements from the ITMs to the ETMs per Sheila's suggestion.
I did not have permissions to write to /opt/rtcds/userapps/release/lsc/h1/templates/, so I created two new templates in /opt/rtcds/userapps/release/lsc/h1/scripts/feedforward.
Have not had a chance to fit the MICH FF because I unlocked the IFO during the test.  

That is the only reason we lost lock this evening, had 13 straight hours of IFO time.  

I also altered ALS guardian so that X arm green WFS don't come on.  Mediocre alignment makes the WFS cause locklosses during LOCKING_ALS.
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:26, Sunday 04 November 2018 (45002)

I forgot to log this yesterday, but I noticed that the X arm WFS have been set to off using the gain slider, so that they have not been on during initial alignment unless someone notices and turns them on.  This is probably the reason why we ended up with bad alignments after several inital alignment attempts during the day Friday, so I added a line that turns the WFS gain on in the ENABLE_WFS state.  

I think that we should still be able to turn off the X arm WFS by hand if needed.  It is likely that turning the X arm WFS off in the guardian is also turning off the Y arm WFS, which do work.  We should look into why the X arm WFS don't work anymore.  