Reports until 19:09, Sunday 04 November 2018
H1 ISC
thomas.vo@LIGO.ORG - posted 19:09, Sunday 04 November 2018 (45009)
Trouble relocking after dolphin crashes

Dan Brown, Danny V., TVo

Note for the morning crew, after the frontend restarts from the dolphin crashing, we cleared all the affected watchdogs for SEI and SUS.  However, when we tried to relock, the green WFS wouldn't engage on both arms until we had to do some realignment and then WFS_PUM worked.  It seems like H1:LSC-TR_Y_NORM_MON has an elevated setting, maybe a dark offset somewhere that hasn't been reset?  Also, it seems like the IMC WFS are not engaging as well at first, but once I lowered the threshold on the ASC IMC trigger to 30 instead of 40, they resumed. 

I'm not sure what re-start procedure needs to happen in order to recover from such a dramatic front end bootfest, for now we're leaving the ISC LOCK guardian in down.