stefan.ballmer@LIGO.ORG - posted 14:16, Monday 05 November 2018 (45021)
noise budget from 2018 and 2015 compared
Here are links to Sheila's recent noise budget, and the Evan's noise budget from Sept 2015:

alog 44998: 2018-11-03 (png).
alog 21162: 2015-09-12 (pdf).

Remarks:
 - LSC auxiliary couplings: they are about a factor of 2 higher now than in 2015 at 30Hz.
 - Also, in 2015, we used rolled off the signals faster, but rolled them back up again at higher frequencies to gain back phase. So above 60Hz, LSC AUX was completely out of the picture.
 - ASC noise: at 20Hz the ASC noise is now 10x (!) higher in DARM now compared to 2015. Hang is working on that now.