Reports until 15:30, Monday 05 November 2018
H1 ISC
jenne.driggers@LIGO.ORG - posted 15:30, Monday 05 November 2018 - last comment - 17:51, Monday 05 November 2018(45026)
SRC2 ASC semi-coherent with DARM

SRC2 is pretty coherent with DARM (attached .png, bottom right corner pink and cyan).  I did some injections, so that Sheila can stick these into the noise budget (.xml attachments).  But, we should roll this QPD loop off faster.

Images attached to this report
Non-image files attached to this report
Comments related to this report
hang.yu@LIGO.ORG - 17:51, Monday 05 November 2018 (45032)ISC

After Jenne notice the problem, we put some extra LPs in SRC2 loops.

For the SRC2 P loop, we lowered it DC gain by 3dB from 200 to 140 and added a 4th order ellip filt at 10 Hz with 40 dB attenuation.

For SRC2 Y loop, we tried to put a LP as aggressive as the PIT one but it broke the lock once. So we lowered the SRC2 Y loop gain by 6 dB from 200 to 100 and used a 4th order ellip filt at 12 Hz with 30 dB attenuation.

The LPs seem to improved DARM noise below 30 Hz. See the attached figure.

Images attached to this comment