SRC2 is pretty coherent with DARM (attached .png, bottom right corner pink and cyan). I did some injections, so that Sheila can stick these into the noise budget (.xml attachments). But, we should roll this QPD loop off faster.
After Jenne notice the problem, we put some extra LPs in SRC2 loops.
For the SRC2 P loop, we lowered it DC gain by 3dB from 200 to 140 and added a 4th order ellip filt at 10 Hz with 40 dB attenuation.
For SRC2 Y loop, we tried to put a LP as aggressive as the PIT one but it broke the lock once. So we lowered the SRC2 Y loop gain by 6 dB from 200 to 100 and used a 4th order ellip filt at 12 Hz with 30 dB attenuation.
The LPs seem to improved DARM noise below 30 Hz. See the attached figure.