ETM HWS code updated to export files to HDF5

Following a failed attempt to update the HWS code (aLOG 44365), the ETM HWS code was updated to export the HWS gradient fields to HDF5 files instead of PICKLE. (Using the latest version of the code from the GIT repo).

The display code on those machines has been similarly updated.

I confirmed that the HDF5 files are being archived into the same data directories as the PICKLE files.