We noticed that the DARM noise around 20-30 Hz was not as ''smooth'' as our best references, indicating there were some scattering noises. As the first step, we shook the CPs similarly to what was done in LHO:37053 and then moved their alignments to minimizing the scattering shelves.

The CP moves led to a broadband improvement in DARM from ~15 Hz to ~ 40 Hz. Please see the first attached plot for a noise comparison (red: DARM after moving CP; orange: O3 best reference before the CP move; grey: old best).

==================================================================

Details

We dithered the CPs in length at 0.1 Hz with an amplitude of roughly 20 um (600 ct to SUS-ITMX/Y_R0_DAMP_L_EXC) to create significant scattering shelves in DARM. Then we moved the CPs in P/Y to minimize the shelves.

In the second plot we showed some examples of the scattering shelves. The blue/brown traces were shelves created when we excited CP_Y/X in length, respectively, with the CPs at their original alignments. For CP Y, we were able to reduce the scattering shelf by almost an order of magnitude by moving it in PIT +150 urad and in YAW -50 urad from its original position. For X, we tried to move it +- 100 urad in both P/Y yet the original one seemed to be optimal already.

In the last plot we showed the current alignment of the CPs.

==================================================================

Since our DARM was still not as smooth as LLO, there might still be some scattering from BS AR or ITM ARs that might be worth doing further investigations.

Images attached to this report
Comments related to this report
alena.ananyeva@LIGO.ORG - 09:26, Friday 09 November 2018 (45153)
Attaching a Zemax simulation showing a detector view in front of PR2 baffle
left: before CP alignment change
right: after ITMY CP pitch +150 urad and yaw -50 urad