peter.fritschel@LIGO.ORG - posted 22:26, Friday 09 November 2018 - last comment - 15:09, Saturday 10 November 2018(45183)
ITM ESD Bias: Negligible effect on DARM

Stefan, Craig, Peter

We applied DC Bias to the ESD of both ITMs, ranging from positive to negative full scale (+437 V to -437 V). Looks like there might be a very small increase in low frequency DARM noise for +437 V bias on ITMY (see attached plot), but for all other applied biases there was not even such a hint of a noise increase.

Non-image files attached to this report
Comments related to this report
peter.fritschel@LIGO.ORG - 15:09, Saturday 10 November 2018 (45190)

This morning we also re-tested the effect of ETMY ESD bias. No effect visible in DARM in changing bias from 0 V, to +400 V, to -400 V.