Displaying report 1-1 of 1.
Reports until 18:10, Sunday 11 November 2018
H1 SEI
hugh.radkins@LIGO.ORG - posted 18:10, Sunday 11 November 2018 - last comment - 19:26, Sunday 11 November 2018(45206)
Locking/Disabling SEI HAM6

On site now.  Will head out to lock HAM 6 HEPI and disable the ISI to disconnect cables from feedthrus.  Will comment here when complete.

Comments related to this report
hugh.radkins@LIGO.ORG - 19:26, Sunday 11 November 2018 (45208)

Completed:

Locked HEPI while isolated.  Off in Z about 50um, others DOFs better.  ISI OFFLINE with corner 3 Sensor and coil driver chassis powered down.  Corner 3 Actuator cables disconnected from chamber feed thru.  CPS cables left attached for their protection.

Clean room running now.  Leaving site.

Displaying report 1-1 of 1.